Line 45: | Line 45: | ||
|- | |- | ||
! Build Volume | ! Build Volume | ||
| 16x12x10 in <br> 400x300x250 mm <br> '''or'''<br> 24x16x10 in <br> 600x400x250 mm | |||
| 24x16x20 in <br> 600x400x500 mm | | 24x16x20 in <br> 600x400x500 mm | ||
| 16x12x10 in <br> 400x300x250 mm | |||
|- | |- | ||
! Bed <br> Temperatures | ! Bed <br> Temperatures |
Revision as of 18:44, 14 June 2018
Hydra Models
The Hydras are our Gantry models, introduced in 2016. In these models we move the heads in the X/Y and the bed only in the Z, allowing for faster print speeds and heavier fixturing.
Comparison
The following chart compares and contrasts the various Hydra models:
Designation | Hydra 16A Freestanding Heated |
Hydra 17A Benchtop Heated | |
---|---|---|---|
Hydra 16A-S Standard |
Hydra 16A-T Tall |
Hydra 340 | |
Target Users |
Industrial Manufacturing | Commercial Manufacturing | |
Image | |||
Placement Mechanism |
Freestanding (Floor) Model Gantry Design |
Benchtop Model Gantry Design | |
Exterior Dimensions, XxYxZ (closed) |
48x35x50 in 120x88x125 cm |
48x35x60 in 120x88x153 cm |
41x27x28 in 104x69x71 cm |
Power Requirements |
15A / 110VAC / 60 Hz 8A / 220VAC / 50Hz |
15A / 110VAC / 60 Hz 8A / 220VAC / 50Hz | |
Build Volume | 16x12x10 in 400x300x250 mm or 24x16x10 in 600x400x250 mm |
24x16x20 in 600x400x500 mm |
16x12x10 in 400x300x250 mm |
Bed Temperatures |
120°C 200°C option sub-ambient option |
120°C 200°C option sub-ambient option | |
200°C Hotbed Note |
Note that 200°C beds larger than 400x300mm require 230VAC for optimal heating. | ||
X/Y Printing Speeds |
Up to 50 mm/sec | Up to 50 mm/sec | |
Enclosure | Heated to 55°C | Heated to 55°C | |
Motion Control | 3-Phase with Closed-Loop Feedback |
3-Phase with Closed-Loop Feedback | |
Positional Resolution X/Y/Z in µm |
6 / 6 / 1 | 6 / 6 / 1 | |
Positional Accuracy X/Y/Z in µm |
60 / 60 / 10 | 60 / 60 / 10 | |
Positional Repeatability X/Y/Z in µm |
60 / 60 / 10 | 60 / 60 / 10 | |
Precise X/Y Output for Bioplots |
100 µm lines 200 µm spacing |
100 µm lines 200 µm spacing | |
Precise Z output for Bioplots |
25 µm layers | 25 µm layers | |
Tool Positions Optional |
Five Ten |
Five | |
Cold Flow Options |
All EMO, COD, SDS, CSD, DSD and SMH Heads | ||
Warm Flow Options |
All VOL, VCD, KRA and KCD Heads | ||
Hot Flow Options |
All MK1-250, MK2-250 and MK1-450 Heads | ||
Low Power Laser Options |
5w, 808nm, AlGaAs Diode and/or 6w, 450nm, GaN Diode | ||
High Power Laser Options |
40w ~10 µm, CO2 | Not Applicable | 40w ~10 µm, CO2 |
Spindle Tool Compatibility |
Standard Three-Phase |
Standard | |
Other Options |
Quiet Storm Fan, Microscope |