Line 46: | Line 46: | ||
| = 317.8 µL displacement. | | = 317.8 µL displacement. | ||
|- | |- | ||
! | ! And so: | ||
! colspan="5" | 86,400 pulses = 317.8 µL, or 271.9 pulses/µL | ! colspan="5" | 86,400 pulses = 317.8 µL, or 271.9 pulses/µL | ||
|} | |} |
Revision as of 17:22, 27 July 2020
This is to explain the various gearing on our different heads.
EMO and VOL
The EMO and VOL heads each have:
A. A 1.8° stepping motor, running in 1/16th microstep mode; B. A 27:1 planetary gear; C. A 1:1 drive screw coupling; D. A drive screw with a pitch of 18 threads per inch, or 1.411 thread per mm; E. And a reservoir with a 17 mm diameter, or 227 mm2 cross section.
The table below explains how a certain number of pulses (or microsteps) on the motor will generate a certain volume displacement in the reservoir - the pulses/µL number that we need to control the material flow.