=== Version 3.x ===
=== Version 3.x ===
If Repetrel doesn't automatically connect to the printer at this time, we may need to manually set the COM port:
In Repetrel, click the HELP menu and select "List USB devices on this computer":
[[File:Comlink3_listUSB.png|300px|COM Tab]]
You should see not only the FT232R USB UART under Devices:
[[File:Comlink3_DevsUART.png|300px|Devices & Printers]]
But also, under Unspecified, you should see the STMicroelectronics Virtual COM Port:
[[File:Comlink3_DevsVCP.png|300px|Devices & Printers]]
This should have a com port listed at the end of the name, in parentheses. Double-click to open Properties:
[[File:Comlink3_UART_Props.png|300px|Devices & Printers]]
Click on the Hardware tab and see if there are any warnings (a hazard icon would be present):
[[File:Comlink3_UART_Props_HW.png|300px|Devices & Printers]]
If you have the hazard icon, perform the '''[http://hyrel3d.net/wiki/index.php/Drivers| Installing Drivers]''' tasks again.
If all looks well, read the port number; this is the port you want to use to connect:
[[File:Comlink3_UART_Props_HW2.png|300px|Devices & Printers]]
Select that COM port, ensure the rate is set to 38400, click Apply, then click PING:
[[File:Comlink3_4.png|300px|Apply and Ping]]
You should now be connected over the UART protocol:
[[File:Comlink3_5.png|400px|Apply and Ping]]
=== Version 4.x ===


If Repetrel doesn't automatically connect to the printer at this time, we may need to manually set the COM port:
If Repetrel doesn't automatically connect to the printer at this time, we may need to manually set the COM port:

Revision as of 12:57, 26 January 2021

Whether connecting from the Tablet or another PC, we cannot control what COM port the printer is assigned to. Here is what to do if Repetrel is not connecting to the Printer (the motion controller).

Quick Note: 90% of the time, when the unit is powered with no connectivity, it is either a loose connection on the USB cable or the wrong COM port has been selected.

Click any image for a larger version.


Please note that this page is for communications issues. If Repetrel is showing your heads and printer, but you CANNOT OPERATE (heat, move) your heads or bed, you may not have a communications issue, but CHECK IF YOUR EMERGENCY STOP IS ENGAGED. The E-Stop will prevent power to your motors and heating elements.

NOTE: Standard troubleshooting is based on controlling the printer from the tablet we ship (and test) with. If you are controlling your printer from a computer other than the tablet we ship with, PLEASE reseat your USB cables and then follow the instructions at USB.


Video

The following video is all that most people will need to reset their COM port:

https://www.youtube.com/watch?v=RlJqdhtpB6Q

Is the Printer Powered Up?

Ensure that:

  1. The power supply is plugged into a known good receptacle;
  2. The power supply is set to the proper voltage (115/230 VAC);
  3. The power supply is turned on; and
  4. The power button is pressed in.

When this is the case, on a 30M, the Power and Reset buttons should be illuminated:

Power, Reset Buttons

When your printer is powered up, as above, we move on to the motion controller:

Is the Motion Controller working?

When the motion controller is working properly and communicating with another device over CANBUS (the hotbed controller and any loaded heads), you should see a blinking green "heartbeat" light on the front of the spine, about 6cm up from the bottom and about 2cm in from the right:

Heartbeat LED

If the heartbeat is missing, first unload any print heads and reset the printer:

Power, Reset Buttons

If this was unsuccessful, disconnect the hotbed controller by engaging the emergency stop, then grabbing all wires firmly and pulling to the left; then load a print head and reset the printer:

Unplug the Hotbed Controller Unplug the Hotbed Controller Unplug the Hotbed Controller

If the heartbeat is still missing, there are two potential causes:

One, the firmware on the motion controller may not be in sync with the firmware on the other device(s). Our fix for this is to flash a known version to the motion controller and a compatible version to the print heads. However, this is not usually the root cause unless you are working with some older equipment which has not been properly updated during 2016 or later.

Two, we may need to press the reset button on the motion controller itself:

  1. Use a 2.5mm hex driver to remove the screws holding the rear cover in place;
  2. Press the reset button on the motion controller card:

Motion Controller Reset Button

If we still haven't restored the heartbeat, there is some issue with the motion controller itself, so we should flash the current firmware onto it again:

In Repetrel, click File > Update Firmware > 407 Motion Controller:

Flashing the Motion Controller, Image 1

You should see the green message "Connected" when connected. If you see a yellow message "Not connected Check Boot Switch Press RESET Button" instead, check your USB connectivity to the printer and press the reset button. Once you are on firmware 2.4 and above, you will not need to change the boot/run switch to connect or flash.

Next, click Select File, highlight the correct file, and click Open:

Flashing the Motion Controller, Image 2

Last, click Program and wait for the process to complete and the window to close.

Flashing the Motion Controller, Image 3

Now you should have the heartbeat. If not, there can be two causes.

1. You might not have good CANBUS communications. We need at least one device to be communicating properly, and NO devices on mismatched firmware (since some of the protocols have changed over the years); this includes the hotbed controller and the heads. To determine if this is the case, disconnect the hotbed controller by engaging the emergency stop, then grabbing all wires firmly and pulling to the left; then load a print head and reset the printer:

Unplug the Hotbed Controller Unplug the Hotbed Controller Unplug the Hotbed Controller

2. We might have a problem with the 407 Motion Controller. We have had less than 1% of these go bad, and when they do it has been after a severe power surge. Contact us if this is the case.

Once you have the heartbeat, we can proceed:

Are we Connected?

Please note that with Repetrel v3 and above, even though you are still using a USB cable, you MUST connect over the a virtual COM port to the UART. The process for selecting the COM port is the same.

Version 2.x

Note: in v3 and later, the "refresh" functionality is activated by clicking on the COM menu button.

If Repetrel doesn't automatically connect to the printer at this time, we may need to manually set the COM port:

In Repetrel, click on the Comm Link tab:

Com Link Tab

Click on the COM# button and select Refresh:

Refresh

Click on the COM# button again, and select the highest COM port shown; you may need to cycle through all available ports, but it is usually the highest numbered one displayed:

Set Com Port

Ensure that the communication rate is set to 38400; click Apply, and then click Ping. You should get the message "Printer Connected" as shown below:

Apply and Ping

Version 3.x

If Repetrel doesn't automatically connect to the printer at this time, we may need to manually set the COM port:

In Repetrel, click the HELP menu and select "List USB devices on this computer":

COM Tab

You should see not only the FT232R USB UART under Devices:

Devices & Printers

But also, under Unspecified, you should see the STMicroelectronics Virtual COM Port:

Devices & Printers

This should have a com port listed at the end of the name, in parentheses. Double-click to open Properties:

Devices & Printers

Click on the Hardware tab and see if there are any warnings (a hazard icon would be present):

Devices & Printers

If you have the hazard icon, perform the Installing Drivers tasks again.

If all looks well, read the port number; this is the port you want to use to connect:

Devices & Printers

Select that COM port, ensure the rate is set to 38400, click Apply, then click PING:

Apply and Ping

You should now be connected over the UART protocol:

Apply and Ping

Version 4.x

If Repetrel doesn't automatically connect to the printer at this time, we may need to manually set the COM port:

In Repetrel, click the HELP menu and select "List USB devices on this computer":

COM Tab

You should see not only the FT232R USB UART under Devices:

Devices & Printers

But also, under Unspecified, you should see the STMicroelectronics Virtual COM Port:

Devices & Printers

This should have a com port listed at the end of the name, in parentheses. Double-click to open Properties:

Devices & Printers

Click on the Hardware tab and see if there are any warnings (a hazard icon would be present):

Devices & Printers

If you have the hazard icon, perform the Installing Drivers tasks again.

If all looks well, read the port number; this is the port you want to use to connect:

Devices & Printers

Select that COM port, ensure the rate is set to 38400, click Apply, then click PING:

Apply and Ping

You should now be connected over the UART protocol:

Apply and Ping

Heads Unresponsive?

If your head is plugged in, but not working as expected, there are a few things that might be wrong.

Each head has both a mechanical connection and an electronic connection.

The mechanical connection is to lock the head rigidly in place, and also to adjust so that multiple heads can all have their nozzles at the same "Z-zero" height.

The electronic connection provides power to the head (for motor and, if present, heater) as well as bi-directional communications between the head and the motion controller (and from there, to Repetrel).

  1. With the head unloaded, loosen the two screws on the back by about 90-180 degrees - just enough to be able to wiggle the circuit board.
  2. Load the head as far down as it will go, and then tighten the thumbscrew (or, on Hydras, the set screw with the 3mm hex driver - called a thumbscrew hereafter).
  3. Now seat the circuit board so that it makes full contact along the entire connector; improper seating may turn the LEDs on without providing power.
  4. Push your emergency stop in, seat the spacer board all the way down, and tighten the screws.

Ready to go!