The Hydras are our Gantry models, introduced in 2016. In these models we move the heads in the X/Y and the bed only in the Z, allowing for faster print speeds and heavier fixturing.
Comparison
The following chart compares and contrasts the various Hydra models:
Designation | Freestanding Enclosed, Heated |
Freestanding Enclosed, Heated |
Benchtop Enclosed, Heated |
---|---|---|---|
Hydra 16AS Standard |
Hydra 16AT Tall |
Hydra 21 | |
Target Users |
Laboratory Research | Laboratory Research | Laboratory Research |
Image |
| ||
Placement Mechanism |
Freestanding (Floor) Model Gantry Design |
Freestanding (Floor) Model Gantry Design |
Benchtop Model Gantry Design |
Exterior Dimensions, XxYxZ (closed) |
48x35x50 in 120x88x125 cm |
48x35x60 in 120x88x153 cm |
42x24x33 in 107x61x84 cm |
Power Requirements |
15 A / 110-120 VAC / 60 Hz 8 A / 220-240 VAC / 50 Hz | ||
Build Volume | 16x12x10 in 400x300x250 mm or 24x16x10 in 600x400x250 mm |
16x12x20 in 600x400x500 mm or 24x16x20 in 600x400x500 mm |
16x12x10 in 400x300x250 mm |
Bed Temperatures |
120°C / 200°C option / -5°C option Note that 200°C beds larger than 400x300mm require 230VAC for optimal heating. | ||
Bed RTDs | 1k PLAT | ||
X/Y Printing Speeds |
Up to 60 mm/sec | ||
Enclosure | Heated to 55°C | ||
Motion Control | 3-Phase with Closed-Loop Feedback | ||
Positional Resolution X/Y/Z in µm |
6 / 6 / 1 | ||
Positional Accuracy X/Y/Z in µm |
60 / 60 / 10 | ||
Positional Repeatability X/Y/Z in µm |
60 / 60 / 10 | ||
Precise X/Y Output for Bioplots |
100 µm lines 200 µm spacing | ||
Precise Z output for Bioplots |
25 µm layers | ||
Tool Positions Optional |
Five Ten | ||
Reservoir Ambient Options |
All EMO, SDS, DSD and SMH Heads | ||
Reservoir Temp Ctrl Options |
All VOL, KRA, TAM, RSD, and HSD Heads | ||
Filament Options |
All MK1-250, MK2-250 and MK1-450 Heads | ||
Low Power Laser Options |
6w, 450nm, GaN Diode and 2w, 450nm GaN Diode | ||
High Power Laser Options |
40w ~10 µm, CO2 | (coming soon) | |
Spindle Tool Compatibility |
Standard Three-Phase | ||
Max Axes | Max of 5: X, Y, Z Optional 4th A Axis (Lathe) Optional 4/5th Axes (Trunion) | ||
Pick & Place Compatibility |
Yes | ||
Other Options |
Quiet Storm Fan, Microscope |
The Hydra Series
The Hydra 16A models have hard resolution (with encoder feedback) of 20 microns in the X and Y, and 0.8 microns in the Z in standard mode. In microstepping mode, we can achieve soft resolution of 4 microns in the X and Y. It comes standard with two tool positions, but can take additional yokes to handle more.
There are three models, as detailed above. The differences are:
- The Hydra 16A-S (standard) has a 250mm Z and stands on the floor, with the following options:
- Can take a bed at 400x300mm or 600x400mm at 120°C or 200°C, or a sub-ambient bed;
- Can take the 40W CO2 laser and 5W, 450nm diode laser;
- Can take the Pick and Place setup; and
- Can take the 3-Phase and 1-Phase spindle tools.
- The Hydra 16A-T (tall) has a 500mm Z and stands on the floor, with the following options:
- Can take a bed at 400x300mm or 600x400mm at 120°C or 200°C, or a sub-ambient bed;
- Can take the 5W, 450nm diode laser (NO CO2 LASER);
- Can take the Pick and Place setup; and
- Can take the 3-Phase and 1-Phase spindle tools.
- Overview of the Hydra line