Difference between revisions of "Hydras"
Jump to navigation
Jump to search
(9 intermediate revisions by the same user not shown) | |||
Line 16: | Line 16: | ||
|+ Printer Model Comparison | |+ Printer Model Comparison | ||
! style="width: 10%" rowspan="2"|Designation | ! style="width: 10%" rowspan="2"|Designation | ||
! style="width: 20%" | ! style="width: 20%"|Freestanding <br> Enclosed, Heated | ||
! style="width: 10%"| | ! style="width: 20%"|Freestanding <br> Enclosed, Heated | ||
! style="width: 10%"|Benchtop <br> Enclosed, Heated | |||
|- | |- | ||
! [[Hydras|Hydra]] | ! [[Hydras|Hydra]] 16AS <br> Standard | ||
! [[Hydras|Hydra]] | ! [[Hydras|Hydra]] 16AT <br> Tall | ||
! [[Hydras|Hydra]] | ! [[Hydras|Hydra]] 21 | ||
|- | |- | ||
! Target <br> Users | ! Target <br> Users | ||
| | | Laboratory Research | ||
| | | Laboratory Research | ||
| Laboratory Research | |||
|- | |- | ||
! Image | ! Image | ||
| <gallery>File:Hydra_16A.png</gallery> | |||
| <gallery>File: | | <gallery>File:Hydra_16AT.png</gallery> | ||
| <gallery>H21.png</gallery> | |||
|- | |- | ||
! Placement<br>Mechanism | ! Placement<br>Mechanism | ||
| | | Freestanding (Floor) Model<br>Gantry Design | ||
| Freestanding (Floor) Model<br>Gantry Design | |||
| Benchtop Model<br>Gantry Design | | Benchtop Model<br>Gantry Design | ||
|- | |- | ||
Line 38: | Line 42: | ||
| 48x35x50 in <br> 120x88x125 cm | | 48x35x50 in <br> 120x88x125 cm | ||
| 48x35x60 in <br> 120x88x153 cm | | 48x35x60 in <br> 120x88x153 cm | ||
| | | 42x24x33 in <br> 107x61x84 cm | ||
|- | |- | ||
! Power <br> Requirements | ! Power <br> Requirements | ||
| colspan=" | | colspan="3" | 15 A / 110-120 VAC / 60 Hz <br> 8 A / 220-240 VAC / 50 Hz | ||
|- | |- | ||
! Build Volume | ! Build Volume | ||
| 16x12x10 in <br> 400x300x250 mm <br> '''or'''<br> 24x16x10 in <br> 600x400x250 mm | |||
| 24x16x20 in <br> 600x400x500 mm | | 16x12x20 in <br> 600x400x500 mm <br> '''or''' <br> 24x16x20 in <br> 600x400x500 mm | ||
| 16x12x10 in <br> 400x300x250 mm | |||
|- | |- | ||
! Bed <br> Temperatures | ! Bed <br> Temperatures | ||
| colspan=" | | colspan="3" | 120°C / <span style="color: red;">200°C option</span> / <span style="color: blue;">''-5°C option''</span> <br> ''Note that 200°C beds larger than 400x300mm <br> require 230VAC for optimal heating.'' | ||
|- | |- | ||
! | ! Bed RTDs | ||
| colspan="3" | | | colspan="3" | 1k PLAT | ||
|- | |- | ||
! X/Y Printing<br> Speeds | ! X/Y Printing<br> Speeds | ||
| colspan=" | | colspan="3" | Up to 60 mm/sec | ||
|- | |- | ||
! Enclosure | ! Enclosure | ||
| colspan=" | | colspan="3" | Heated to 55°C | ||
| Heated to 55°C | |||
|- | |- | ||
! Motion Control | ! Motion Control | ||
| colspan=" | | colspan="3" | 3-Phase with <br> Closed-Loop Feedback | ||
| 3-Phase with <br> Closed-Loop Feedback | |||
|- | |- | ||
! Positional Resolution <br> X/Y/Z in µm | ! Positional Resolution <br> X/Y/Z in µm | ||
| colspan=" | | colspan="3" | 6 / 6 / 1 | ||
| 6 / 6 / 1 | |||
|- | |- | ||
! Positional Accuracy <br> X/Y/Z in µm | ! Positional Accuracy <br> X/Y/Z in µm | ||
| colspan=" | | colspan="3" | 60 / 60 / 10 | ||
| 60 / 60 / 10 | |||
|- | |- | ||
! Positional Repeatability <br> X/Y/Z in µm | ! Positional Repeatability <br> X/Y/Z in µm | ||
| colspan=" | | colspan="3" | 60 / 60 / 10 | ||
| 60 / 60 / 10 | |||
|- | |- | ||
! Precise X/Y Output <br> for Bioplots | ! Precise X/Y Output <br> for Bioplots | ||
| colspan=" | | colspan="3" | 100 µm lines <br> 200 µm spacing | ||
| 100 µm lines <br> 200 µm spacing | |||
|- | |- | ||
! Precise Z output <br> for Bioplots | ! Precise Z output <br> for Bioplots | ||
| colspan=" | | colspan="3" | 25 µm layers | ||
| 25 µm layers | |||
|- | |- | ||
! Tool Positions <br> ''Optional'' | ! Tool Positions <br> ''Optional'' | ||
| colspan=" | | colspan="3" | Five <br> ''Ten'' | ||
|- | |- | ||
! | ! Reservoir<br>Ambient <br> Options | ||
|colspan="3"| All [[EMO | |colspan="3"| All [[EMO]], [[SDS]], DSD and SMH Heads | ||
|- | |- | ||
! | ! Reservoir<br>Temp Ctrl<br> Options | ||
|colspan="3"| All [[VOL]], [[ | |colspan="3"| All [[VOL]], [[KRA]], [[TAM]], [[RSD]], and [[HSD]] Heads | ||
|- | |- | ||
! | ! Filament <br> Options | ||
|colspan="3"| All [[MK1-250]], [[MK2-250]] and [[MK1-450]] Heads | |colspan="3"| All [[MK1-250]], [[MK2-250]] and [[MK1-450]] Heads | ||
|- | |- | ||
! Low Power <br> Laser Options | ! Low Power <br> Laser Options | ||
|colspan="3"| | |colspan="3"| 6w, 450nm, GaN Diode and 2w, 450nm GaN Diode | ||
|- | |- | ||
! High Power <br> Laser Options | ! High Power <br> Laser Options | ||
| 40w ~10 µm, CO<sub>2</sub> | | colspan="2" | 40w ~10 µm, CO<sub>2</sub> | ||
| | | (coming soon) | ||
|- | |- | ||
! Spindle Tool <br> Compatibility | ! Spindle Tool <br> Compatibility | ||
| colspan=" | | colspan="3" | Standard <br> Three-Phase | ||
| | |- | ||
! Max Axes | |||
| colspan="3" | Max of 5: X, Y, Z<br>Optional 4th A Axis (Lathe)<br>Optional 4/5th Axes (Trunion) | |||
|- | |||
! Pick & Place <br> Compatibility | |||
| colspan="3" | Yes | |||
|- | |- | ||
! Other <br> Options | ! Other <br> Options | ||
|colspan="3"|Quiet Storm Fan, Microscope | |colspan="3"|Quiet Storm Fan, Microscope | ||
|} | |} | ||
==== The [[Hydras|Hydra]] Series ==== | |||
The [[Hydras|Hydra]] 16A models have hard resolution (with encoder feedback) of 20 microns in the X and Y, and 0.8 microns in the Z in standard mode. In microstepping mode, we can achieve soft resolution of 4 microns in the X and Y. It comes standard with two tool positions, but can take additional yokes to handle more. | |||
There are three models, as detailed above. The differences are: | |||
* The [[Hydras|Hydra]] 16A-S (standard) has a 250mm Z and stands on the floor, with the following options: | |||
** Can take a bed at 400x300mm or 600x400mm at 120°C or 200°C, or a sub-ambient bed; | |||
** Can take the 40W CO2 laser and 5W, 450nm diode laser; | |||
** Can take the Pick and Place setup; and | |||
** Can take the 3-Phase and 1-Phase spindle tools. | |||
* The [[Hydras|Hydra]] 16A-T (tall) has a 500mm Z and stands on the floor, with the following options: | |||
** Can take a bed at 400x300mm or 600x400mm at 120°C or 200°C, or a sub-ambient bed; | |||
** Can take the 5W, 450nm diode laser (NO CO2 LASER); | |||
** Can take the Pick and Place setup; and | |||
** Can take the 3-Phase and 1-Phase spindle tools. | |||
* [[File:Yt.png]] [https://www.youtube.com/watch?v=uACoqtNbXE0 Overview of the [[Hydras|Hydra]] line] |
Latest revision as of 14:07, 24 June 2021
Hydra Models
The Hydras are our Gantry models, introduced in 2016. In these models we move the heads in the X/Y and the bed only in the Z, allowing for faster print speeds and heavier fixturing.
Comparison
The following chart compares and contrasts the various Hydra models:
Designation | Freestanding Enclosed, Heated |
Freestanding Enclosed, Heated |
Benchtop Enclosed, Heated |
---|---|---|---|
Hydra 16AS Standard |
Hydra 16AT Tall |
Hydra 21 | |
Target Users |
Laboratory Research | Laboratory Research | Laboratory Research |
Image |
| ||
Placement Mechanism |
Freestanding (Floor) Model Gantry Design |
Freestanding (Floor) Model Gantry Design |
Benchtop Model Gantry Design |
Exterior Dimensions, XxYxZ (closed) |
48x35x50 in 120x88x125 cm |
48x35x60 in 120x88x153 cm |
42x24x33 in 107x61x84 cm |
Power Requirements |
15 A / 110-120 VAC / 60 Hz 8 A / 220-240 VAC / 50 Hz | ||
Build Volume | 16x12x10 in 400x300x250 mm or 24x16x10 in 600x400x250 mm |
16x12x20 in 600x400x500 mm or 24x16x20 in 600x400x500 mm |
16x12x10 in 400x300x250 mm |
Bed Temperatures |
120°C / 200°C option / -5°C option Note that 200°C beds larger than 400x300mm require 230VAC for optimal heating. | ||
Bed RTDs | 1k PLAT | ||
X/Y Printing Speeds |
Up to 60 mm/sec | ||
Enclosure | Heated to 55°C | ||
Motion Control | 3-Phase with Closed-Loop Feedback | ||
Positional Resolution X/Y/Z in µm |
6 / 6 / 1 | ||
Positional Accuracy X/Y/Z in µm |
60 / 60 / 10 | ||
Positional Repeatability X/Y/Z in µm |
60 / 60 / 10 | ||
Precise X/Y Output for Bioplots |
100 µm lines 200 µm spacing | ||
Precise Z output for Bioplots |
25 µm layers | ||
Tool Positions Optional |
Five Ten | ||
Reservoir Ambient Options |
All EMO, SDS, DSD and SMH Heads | ||
Reservoir Temp Ctrl Options |
All VOL, KRA, TAM, RSD, and HSD Heads | ||
Filament Options |
All MK1-250, MK2-250 and MK1-450 Heads | ||
Low Power Laser Options |
6w, 450nm, GaN Diode and 2w, 450nm GaN Diode | ||
High Power Laser Options |
40w ~10 µm, CO2 | (coming soon) | |
Spindle Tool Compatibility |
Standard Three-Phase | ||
Max Axes | Max of 5: X, Y, Z Optional 4th A Axis (Lathe) Optional 4/5th Axes (Trunion) | ||
Pick & Place Compatibility |
Yes | ||
Other Options |
Quiet Storm Fan, Microscope |
The Hydra Series
The Hydra 16A models have hard resolution (with encoder feedback) of 20 microns in the X and Y, and 0.8 microns in the Z in standard mode. In microstepping mode, we can achieve soft resolution of 4 microns in the X and Y. It comes standard with two tool positions, but can take additional yokes to handle more.
There are three models, as detailed above. The differences are:
- The Hydra 16A-S (standard) has a 250mm Z and stands on the floor, with the following options:
- Can take a bed at 400x300mm or 600x400mm at 120°C or 200°C, or a sub-ambient bed;
- Can take the 40W CO2 laser and 5W, 450nm diode laser;
- Can take the Pick and Place setup; and
- Can take the 3-Phase and 1-Phase spindle tools.
- The Hydra 16A-T (tall) has a 500mm Z and stands on the floor, with the following options:
- Can take a bed at 400x300mm or 600x400mm at 120°C or 200°C, or a sub-ambient bed;
- Can take the 5W, 450nm diode laser (NO CO2 LASER);
- Can take the Pick and Place setup; and
- Can take the 3-Phase and 1-Phase spindle tools.
- Overview of the Hydra line