Difference between revisions of "Hydras"
Jump to navigation
Jump to search
Line 18: | Line 18: | ||
! style="width: 20%" colspan="2"|[[Hydras|Hydra]] 16A Freestanding <br> Heated | ! style="width: 20%" colspan="2"|[[Hydras|Hydra]] 16A Freestanding <br> Heated | ||
|- | |- | ||
! [[Hydras|Hydra]] | ! [[Hydras|Hydra]] 16AS<br>''Standard'' | ||
! [[Hydras|Hydra]] | ! [[Hydras|Hydra]] 16AT<br>''Tall'' | ||
|- | |- | ||
! Target <br> Users | ! Target <br> Users | ||
Line 74: | Line 74: | ||
| colspan="2" | Five <br> ''Ten'' | | colspan="2" | Five <br> ''Ten'' | ||
|- | |- | ||
! | ! colspan="3" | Accessory Options | ||
|- | |- | ||
! | ! [[Reservoir Heads]] | ||
|colspan="2"| All [[VOL]], [[VCD]], [[KRA]] and [[KCD]] Heads | |colspan="2"| All [[EMO]], [[COD]], [[SDS]], [[CSD]], DSD, and SMH Heads <br> All [[VOL]], [[VCD]], [[KRA]], and [[KCD]] Heads | ||
|- | |- | ||
! | ! [[Filament Heads]] | ||
|colspan="2"| All [[MK1-250]], [[MK2-250]] and [[ | |colspan="2"| All [[MK1-250]], [[MK2-250]], [[MK1-450]], [[HT-150]], and [[HT-450]] Heads | ||
|- | |- | ||
! Low Power <br> Laser Options | ! Low Power <br> Laser Options | ||
|colspan="2"| 5w, 808nm, AlGaAs Diode and/or 6w, 450nm, GaN Diode | |colspan="2"| 5w, 808nm, AlGaAs Diode and/or 6w, 450nm, GaN Diode | ||
|- | |- | ||
! High Power <br> Laser Options | ! High Power <br> Laser Options | ||
| 40w ~10 µm, CO<sub>2</sub> | | 40w ~10 µm, CO<sub>2</sub> | ||
| ''Not | | ''Not Available'' | ||
|- | |- | ||
! Spindle Tool <br> Compatibility | ! Spindle Tool <br> Compatibility |
Revision as of 12:44, 22 August 2019
Hydra Models
The Hydras are our Gantry models, introduced in 2016. In these models we move the heads in the X/Y and the bed only in the Z, allowing for faster print speeds and heavier fixturing.
Comparison
The following chart compares and contrasts the various Hydra models:
Designation | Hydra 16A Freestanding Heated | |
---|---|---|
Hydra 16AS Standard |
Hydra 16AT Tall | |
Target Users |
Industrial Manufacturing | |
Image | ||
Placement Mechanism |
Freestanding (Floor) Model Gantry Design | |
Exterior Dimensions, XxYxZ (closed) |
48x35x50 in 120x88x125 cm |
48x35x60 in 120x88x153 cm |
Power Requirements |
15A / 110VAC / 60 Hz 8A / 220VAC / 50Hz | |
Build Volume | 16x12x10 in 400x300x250 mm or 24x16x10 in 600x400x250 mm |
24x16x20 in 600x400x500 mm |
Bed Temperatures |
120°C 200°C option sub-ambient option | |
200°C Hotbed Note |
Note that 200°C beds larger than 400x300mm require 230VAC for optimal heating. | |
X/Y Printing Speeds |
Up to 50 mm/sec | |
Enclosure | Heated to 55°C | |
Motion Control | 3-Phase with Closed-Loop Feedback | |
Positional Resolution X/Y/Z in µm |
6 / 6 / 1 | |
Positional Accuracy X/Y/Z in µm |
60 / 60 / 10 | |
Positional Repeatability X/Y/Z in µm |
60 / 60 / 10 | |
Precise X/Y Output for Bioplots |
100 µm lines 200 µm spacing | |
Precise Z output for Bioplots |
25 µm layers | |
Tool Positions Optional |
Five Ten | |
Accessory Options | ||
Reservoir Heads | All EMO, COD, SDS, CSD, DSD, and SMH Heads All VOL, VCD, KRA, and KCD Heads | |
Filament Heads | All MK1-250, MK2-250, MK1-450, HT-150, and HT-450 Heads | |
Low Power Laser Options |
5w, 808nm, AlGaAs Diode and/or 6w, 450nm, GaN Diode | |
High Power Laser Options |
40w ~10 µm, CO2 | Not Available |
Spindle Tool Compatibility |
Standard Three-Phase | |
Other Options |
Quiet Storm Fan, Microscope |
The Hydra Series
The Hydra 16A models have hard resolution (with encoder feedback) of 20 microns in the X and Y, and 0.8 microns in the Z in standard mode. In microstepping mode, we can achieve soft resolution of 4 microns in the X and Y. It comes standard with two tool positions, but can take additional yokes to handle more.
There are three models, as detailed above. The differences are:
- The Hydra 16A-S (standard) has a 250mm Z and stands on the floor, with the following options:
- Can take a bed at 400x300mm or 600x400mm at 120°C or 200°C, or a sub-ambient bed;
- Can take the 40W CO2 laser and 5W, 450nm diode laser;
- Can take the Pick and Place setup; and
- Can take the 3-Phase and 1-Phase spindle tools.
- The Hydra 16A-T (tall) has a 500mm Z and stands on the floor, with the following options:
- Can take a bed at 400x300mm or 600x400mm at 120°C or 200°C, or a sub-ambient bed;
- Can take the 5W, 450nm diode laser (NO CO2 LASER);
- Can take the Pick and Place setup; and
- Can take the 3-Phase and 1-Phase spindle tools.
- Overview of the Hydra line