Difference between revisions of "Main Page"

From Hyrel3D
Jump to navigation Jump to search
Line 18: Line 18:
Cold Flow means fluid (non-filament-based) materials which are deposited at room temperature, with or without UV Crosslinking.
Cold Flow means fluid (non-filament-based) materials which are deposited at room temperature, with or without UV Crosslinking.


====Materials====
====Materials, Cold Flow====


<div style="column-count:5;-moz-column-count:5;-webkit-column-count:5">
*[[3P Quick Cure Clay]]
*[[Adhesives]]
*[[Adhesives]]
*[[Clay]]
*[[Clay]]
Line 25: Line 27:
*[[Fimo]]
*[[Fimo]]
*[[Glue]]
*[[Glue]]
*[[Kato]]
*[[Metal Clay]], including Precious Metal Clay (PMC)
*[[Metal Clay]], including Precious Metal Clay (PMC)
*[[Modeling Clay]]
*[[Modeling Clay]]
Line 35: Line 38:
*[[Sculpey]]
*[[Sculpey]]
*[[Sugru]]
*[[Sugru]]
</div>
====Heads, Cold Flow====


====Heads====
{| border="1" class="wikitable sortable" style="width: 85%;"
|+ Cold Flow Head Properties
! style="width: 15%;" | Head
! style="width: 15%;" | Max Temp
! style="width: 15%;" | Container
! style="width: 15%;" | Capacity
! style="width: 15%;" | Nozzle
! style="width: 15%;" | UV Crosslinking
|-
! [[EMO-25]]
| Ambient
| Aluminum
| 25cc
| 1.5mm, 2.0mm, Luer
| No
|-
! [[COD-25]]
| Ambient
| Aluminum
| 25cc
| Luer
| Yes
|-
! [[SDS-5]]
| Ambient
| Syringe
| 05cc
| Luer
| No
|-
! [[CSD-5]]
| Ambient
| Syringe
| 05cc
| Luer
| Yes
|-
! [[SDS-10]]
| Ambient
| Syringe
| 10cc
| Luer
| No
|-
! [[CSD-10]]
| Ambient
| Syringe
| 10cc
| Luer
| Yes
|-
! [[SDS-30]]
| Ambient
| Syringe
| 30cc
| Luer
| No
|-
! [[CSD-30]]
| Ambient
| Syringe
| 30cc
| Luer
| Yes
|-
! [[SDS-60]]
| Ambient
| Syringe
| 60cc
| Luer
| No
|-
! [[CSD-60]]
| Ambient
| Syringe
| 60cc
| Luer
| Yes
|-
|}


*The [[EMO-25]] prints in Cold Flow materials at room temperature, with the supplied nozzles or commonly available needles with our [[Luer Tip Adapter]].
*The [[COD-25]] prints in Cold Flow materials at room temperature with [[LED Crosslinking]], with our [[Luer Tip Adapter]].


===Warm Flow===
===Warm Flow===
Line 49: Line 132:
*[[Adhesives]]
*[[Adhesives]]
*[[Fimo]]
*[[Fimo]]
*[[Kato]]
*[[Glue]]
*[[Glue]]
*[[Plasticine]]
*[[Plasticine]]

Revision as of 15:17, 28 January 2016

Printers

As of Jan, 2016, Hyrel Printers are available in two models: Engines and Systems.

  • Engines are open-air models. Detailed information is on the Engines page.
  • Systems are enclosed models. Detailed information is on the Systems page.

Filaments, Heads and Flow

We break down our deposition methods based on temperature, as follows:

Cold Flow

Cold Flow means fluid (non-filament-based) materials which are deposited at room temperature, with or without UV Crosslinking.

Materials, Cold Flow

Heads, Cold Flow

Cold Flow Head Properties
Head Max Temp Container Capacity Nozzle UV Crosslinking
EMO-25 Ambient Aluminum 25cc 1.5mm, 2.0mm, Luer No
COD-25 Ambient Aluminum 25cc Luer Yes
SDS-5 Ambient Syringe 05cc Luer No
CSD-5 Ambient Syringe 05cc Luer Yes
SDS-10 Ambient Syringe 10cc Luer No
CSD-10 Ambient Syringe 10cc Luer Yes
SDS-30 Ambient Syringe 30cc Luer No
CSD-30 Ambient Syringe 30cc Luer Yes
SDS-60 Ambient Syringe 60cc Luer No
CSD-60 Ambient Syringe 60cc Luer Yes


Warm Flow

Warm Flow means fluid (non-filament-based) materials which are deposited at up to 100°C, with or without UV Crosslinking.

Materials

Note that some materials (like Fimo, Plasticine and Sculpey) flow more freely when slightly above room temperature, and perhaps too freely at higher temperatures.

Heads

Hot Flow

Hot Flow means (1.75mm diameter) filament-based materials which are deposited at up to 250°C, with