Difference between revisions of "Hydras"
Jump to navigation
Jump to search
Line 17: | Line 17: | ||
! style="width: 10%" rowspan="2"|Designation | ! style="width: 10%" rowspan="2"|Designation | ||
! style="width: 20%" colspan="2"|[[Hydras|Hydra]] 16A Freestanding <br> Heated | ! style="width: 20%" colspan="2"|[[Hydras|Hydra]] 16A Freestanding <br> Heated | ||
|- | |- | ||
! [[Hydras|Hydra]] 16A-S<br>''Standard'' | ! [[Hydras|Hydra]] 16A-S<br>''Standard'' | ||
! [[Hydras|Hydra]] 16A-T<br>''Tall'' | ! [[Hydras|Hydra]] 16A-T<br>''Tall'' | ||
|- | |- | ||
! Target <br> Users | ! Target <br> Users | ||
| colspan="2" | Industrial Manufacturing | | colspan="2" | Industrial Manufacturing | ||
|- | |- | ||
! Image | ! Image | ||
| colspan="2" | <gallery>File:Hydra_16A.png</gallery> | | colspan="2" | <gallery>File:Hydra_16A.png</gallery> | ||
|- | |- | ||
! Placement<br>Mechanism | ! Placement<br>Mechanism | ||
| colspan="2" | Freestanding (Floor) Model<br>Gantry Design | | colspan="2" | Freestanding (Floor) Model<br>Gantry Design | ||
|- | |- | ||
! Exterior Dimensions, <br> XxYxZ (closed) | ! Exterior Dimensions, <br> XxYxZ (closed) | ||
| 48x35x50 in <br> 120x88x125 cm | | 48x35x50 in <br> 120x88x125 cm | ||
| 48x35x60 in <br> 120x88x153 cm | | 48x35x60 in <br> 120x88x153 cm | ||
|- | |- | ||
! Power <br> Requirements | ! Power <br> Requirements | ||
| colspan="2" | 15A / 110VAC / 60 Hz <br> 8A / 220VAC / 50Hz | | colspan="2" | 15A / 110VAC / 60 Hz <br> 8A / 220VAC / 50Hz | ||
|- | |- | ||
! Build Volume | ! Build Volume | ||
| 16x12x10 in <br> 400x300x250 mm <br> '''or'''<br> 24x16x10 in <br> 600x400x250 mm | | 16x12x10 in <br> 400x300x250 mm <br> '''or'''<br> 24x16x10 in <br> 600x400x250 mm | ||
| 24x16x20 in <br> 600x400x500 mm | | 24x16x20 in <br> 600x400x500 mm | ||
|- | |- | ||
! Bed <br> Temperatures | ! Bed <br> Temperatures | ||
| colspan="2" | 120°C <br> ''200°C option'' <br> ''sub-ambient option'' | | colspan="2" | 120°C <br> ''200°C option'' <br> ''sub-ambient option'' | ||
|- | |- | ||
! 200°C Hotbed <br> Note | ! 200°C Hotbed <br> Note | ||
| colspan=" | | colspan="2" | ''Note that 200°C beds larger than 400x300mm require 230VAC for optimal heating.'' | ||
|- | |- | ||
! X/Y Printing<br> Speeds | ! X/Y Printing<br> Speeds | ||
| colspan="2" | Up to 50 mm/sec | | colspan="2" | Up to 50 mm/sec | ||
|- | |- | ||
! Enclosure | ! Enclosure | ||
| colspan="2" | Heated to 55°C | | colspan="2" | Heated to 55°C | ||
|- | |- | ||
! Motion Control | ! Motion Control | ||
| colspan="2" | 3-Phase with <br> Closed-Loop Feedback | | colspan="2" | 3-Phase with <br> Closed-Loop Feedback | ||
|- | |- | ||
! Positional Resolution <br> X/Y/Z in µm | ! Positional Resolution <br> X/Y/Z in µm | ||
| colspan="2" | 6 / 6 / 1 | | colspan="2" | 6 / 6 / 1 | ||
|- | |- | ||
! Positional Accuracy <br> X/Y/Z in µm | ! Positional Accuracy <br> X/Y/Z in µm | ||
| colspan="2" | 60 / 60 / 10 | | colspan="2" | 60 / 60 / 10 | ||
|- | |- | ||
! Positional Repeatability <br> X/Y/Z in µm | ! Positional Repeatability <br> X/Y/Z in µm | ||
| colspan="2" | 60 / 60 / 10 | | colspan="2" | 60 / 60 / 10 | ||
|- | |- | ||
! Precise X/Y Output <br> for Bioplots | ! Precise X/Y Output <br> for Bioplots | ||
| colspan="2" | 100 µm lines <br> 200 µm spacing | | colspan="2" | 100 µm lines <br> 200 µm spacing | ||
|- | |- | ||
! Precise Z output <br> for Bioplots | ! Precise Z output <br> for Bioplots | ||
| colspan="2" | 25 µm layers | | colspan="2" | 25 µm layers | ||
|- | |- | ||
! Tool Positions <br> ''Optional'' | ! Tool Positions <br> ''Optional'' | ||
| colspan="2" | Five <br> ''Ten'' | | colspan="2" | Five <br> ''Ten'' | ||
|- | |- | ||
! Cold Flow <br> Options | ! Cold Flow <br> Options | ||
|colspan=" | |colspan="2"| All [[EMO]], [[COD]], [[SDS]], [[CSD]], DSD and SMH Heads | ||
|- | |- | ||
! Warm Flow <br> Options | ! Warm Flow <br> Options | ||
|colspan=" | |colspan="2"| All [[VOL]], [[VCD]], [[KRA]] and [[KCD]] Heads | ||
|- | |- | ||
! Hot Flow <br> Options | ! Hot Flow <br> Options | ||
|colspan=" | |colspan="2"| All [[MK1-250]], [[MK2-250]] and [[MK1-450]] Heads | ||
|- | |- | ||
! Low Power <br> Laser Options | ! Low Power <br> Laser Options | ||
|colspan=" | |colspan="2"| 5w, 808nm, AlGaAs Diode and/or 6w, 450nm, GaN Diode | ||
|- | |- | ||
Line 108: | Line 90: | ||
| 40w ~10 µm, CO<sub>2</sub> | | 40w ~10 µm, CO<sub>2</sub> | ||
| ''Not Applicable'' | | ''Not Applicable'' | ||
|- | |- | ||
! Spindle Tool <br> Compatibility | ! Spindle Tool <br> Compatibility | ||
| colspan="2" | Standard <br> Three-Phase | | colspan="2" | Standard <br> Three-Phase | ||
|- | |- | ||
! Other <br> Options | ! Other <br> Options | ||
|colspan=" | |colspan="2"|Quiet Storm Fan, Microscope | ||
|} | |} | ||
Revision as of 15:01, 3 September 2018
Hydra Models
The Hydras are our Gantry models, introduced in 2016. In these models we move the heads in the X/Y and the bed only in the Z, allowing for faster print speeds and heavier fixturing.
Comparison
The following chart compares and contrasts the various Hydra models:
Designation | Hydra 16A Freestanding Heated | |
---|---|---|
Hydra 16A-S Standard |
Hydra 16A-T Tall | |
Target Users |
Industrial Manufacturing | |
Image | ||
Placement Mechanism |
Freestanding (Floor) Model Gantry Design | |
Exterior Dimensions, XxYxZ (closed) |
48x35x50 in 120x88x125 cm |
48x35x60 in 120x88x153 cm |
Power Requirements |
15A / 110VAC / 60 Hz 8A / 220VAC / 50Hz | |
Build Volume | 16x12x10 in 400x300x250 mm or 24x16x10 in 600x400x250 mm |
24x16x20 in 600x400x500 mm |
Bed Temperatures |
120°C 200°C option sub-ambient option | |
200°C Hotbed Note |
Note that 200°C beds larger than 400x300mm require 230VAC for optimal heating. | |
X/Y Printing Speeds |
Up to 50 mm/sec | |
Enclosure | Heated to 55°C | |
Motion Control | 3-Phase with Closed-Loop Feedback | |
Positional Resolution X/Y/Z in µm |
6 / 6 / 1 | |
Positional Accuracy X/Y/Z in µm |
60 / 60 / 10 | |
Positional Repeatability X/Y/Z in µm |
60 / 60 / 10 | |
Precise X/Y Output for Bioplots |
100 µm lines 200 µm spacing | |
Precise Z output for Bioplots |
25 µm layers | |
Tool Positions Optional |
Five Ten | |
Cold Flow Options |
All EMO, COD, SDS, CSD, DSD and SMH Heads | |
Warm Flow Options |
All VOL, VCD, KRA and KCD Heads | |
Hot Flow Options |
All MK1-250, MK2-250 and MK1-450 Heads | |
Low Power Laser Options |
5w, 808nm, AlGaAs Diode and/or 6w, 450nm, GaN Diode | |
High Power Laser Options |
40w ~10 µm, CO2 | Not Applicable |
Spindle Tool Compatibility |
Standard Three-Phase | |
Other Options |
Quiet Storm Fan, Microscope |
The Hydra Series
The Hydra 16A and 17A models have hard resolution (with encoder feedback) of 20 microns in the X and Y, and 0.8 microns in the Z in standard mode. In microstepping mode, we can achieve soft resolution of 4 microns in the X and Y. It comes standard with two tool positions, but can take additional yokes to handle more.
There are three models, as detailed above. The differences are:
- The Hydra 16A-S (standard) has a 250mm Z and stands on the floor, with the following options:
- Can take a bed at 400x300mm or 600x400mm at 120°C or 200°C, or a sub-ambient bed;
- Can take the 40W CO2 laser and 5W, 450nm diode laser;
- Can take the Pick and Place setup; and
- Can take the 3-Phase and 1-Phase spindle tools.
- The Hydra 16A-T (tall) has a 500mm Z and stands on the floor, with the following options:
- Can take a bed at 400x300mm or 600x400mm at 120°C or 200°C, or a sub-ambient bed;
- Can take the 5W, 450nm diode laser (NO CO2 LASER);
- Can take the Pick and Place setup; and
- Can take the 3-Phase and 1-Phase spindle tools.
- The Hydra 17A has a 250mm Z and sits on a workbench or countertop, with the following options:
- Can take a bed at 400x300mm at 120°C or 200°C, or a sub-ambient bed;
- Can take the 40W CO2 laser and 5W, 450nm diode laser;
- Can take the Pick and Place setup; and
- Can take the 3-Phase and 1-Phase spindle tools.
- Overview of the Hydra line