Difference between revisions of "GCode Header"
Jump to navigation
Jump to search
Line 11: | Line 11: | ||
* <span style="color: firebrick;">'''RED'''</span> entries are for the EHR only | * <span style="color: firebrick;">'''RED'''</span> entries are for the EHR only | ||
* <span style="color: navy;">'''BLUE'''</span> entries are for the 16A only | * <span style="color: navy;">'''BLUE'''</span> entries are for the 16A only | ||
* <span style="color: darkorchid;">'''PURPLE'''</span> entries are explanations | |||
This is what your header recipe will look like in Slic3r: | |||
; GENERAL : | |||
N14 ; set line numbers for error logging - Slic3r version | |||
M772 S1 ; reset metrics and arm automatic reporting | |||
M627 X0 Y0 Z0 J-500 K5 ; setup abort action | |||
M107 ; fans/UV ; off | |||
M106 C255 ; fans/UV ; set to 0-255 range | |||
G53 ; clear offsets | |||
G21 ; units : mm | |||
G91 ; coordinatess : relative | |||
G0 Z10 ; drop bed | |||
G90 ; coordinates : absolute | |||
G28 X0 Y0 ; home, goto : X and Y | |||
M229 E1 D1 ; enable E-values (volumetric) | |||
; TEMP CONTROL : | |||
;M190 S[bed_temperature] ; bed temp : set and wait | |||
;M109 T12 S[temperature] ; head temp : set and wait | |||
T2 ; use THIRD tool position from the left | |||
; \\\\\\\\\\\\\\\ END HYREL HEADER for a 30M/ESR with an Unheated Head in T2/T13 - 2021.02.24 /////////////// | |||
(this page is in progress, 20 Apr 2021) | (this page is in progress, 20 Apr 2021) |
Revision as of 18:03, 20 April 2021
At Hyrel, we believe that you must start with a good GCode header to get a good print. Below are explanations of our standard header files. These can be configured in Slic3r under Printer Settings > Custom G-code > Start G-code
- BLACK entries are for every machine
- GREEN entries are recommended, but must be manually entered
- RED entries are for the EHR only
- BLUE entries are for the 16A only
- PURPLE entries are explanations
This is what your header recipe will look like in Slic3r:
; GENERAL : N14 ; set line numbers for error logging - Slic3r version M772 S1 ; reset metrics and arm automatic reporting M627 X0 Y0 Z0 J-500 K5 ; setup abort action M107 ; fans/UV ; off M106 C255 ; fans/UV ; set to 0-255 range G53 ; clear offsets G21 ; units : mm G91 ; coordinatess : relative G0 Z10 ; drop bed G90 ; coordinates : absolute G28 X0 Y0 ; home, goto : X and Y M229 E1 D1 ; enable E-values (volumetric) ; TEMP CONTROL : ;M190 S[bed_temperature] ; bed temp : set and wait ;M109 T12 S[temperature] ; head temp : set and wait T2 ; use THIRD tool position from the left ; \\\\\\\\\\\\\\\ END HYREL HEADER for a 30M/ESR with an Unheated Head in T2/T13 - 2021.02.24 ///////////////
(this page is in progress, 20 Apr 2021)