Difference between revisions of "GCode Header"

From Hyrel3D
Jump to navigation Jump to search
Line 18: Line 18:
This is what your header recipe will look like in Slic3r:
This is what your header recipe will look like in Slic3r:
   
   
  ; GENERAL :
  ; '''REPORTING/ABORTING''' :
   
   
  <span style="color: darkorange;">N14                ; set line numbers for error logging - Slic3r version
  <span style="color: darkorange;">N14                ; set line numbers for error logging - Slic3r version
Line 24: Line 24:
  <span style="color: darkorange;">M627 X0 Y0 Z0 J-500 K5                ; setup abort action</span>
  <span style="color: darkorange;">M627 X0 Y0 Z0 J-500 K5                ; setup abort action</span>
   
   
  <span style="color: black;">;
  <span style="color: black;">M107              ; fans/UV          ; off
M107              ; fans/UV          ; off
  M106 C255          ; fans/UV          ; set to 0-255 range
  M106 C255          ; fans/UV          ; set to 0-255 range
   
   

Revision as of 19:50, 20 April 2021


At Hyrel, we believe that you must start with a good GCode header to get a good print. Below are explanations of our standard header files. These can be configured in Slic3r under Printer Settings > Custom G-code > Start G-code

Sample Header

  • BLACK entries are for every machine
  • GREEN entries are recommended, but must be manually entered
  • RED entries are for the EHR only
  • BLUE entries are for the 16A only
  • PURPLE entries are explanations
  • GOLD entries are optional, but recommended

This is what your header recipe will look like in Slic3r:

; REPORTING/ABORTING :

N14                ; set line numbers for error logging - Slic3r version
M772 S1            ; reset metrics and arm automatic reporting 
M627 X0 Y0 Z0 J-500 K5                 ; setup abort action

; 
M107               ; fans/UV           ; off
M106 C255          ; fans/UV           ; set to 0-255 range

G53                ; clear offsets
G21                ; units             : mm
G91                ; coordinatess      : relative
G0 Z10 	           ; drop bed 
G90                ; coordinates       : absolute

G28 X0 Y0          ; home, goto        : X and Y

M229 E1 D1         ; enable E-values (volumetric)

; TEMP CONTROL :

;M190 S[bed_temperature]          ; bed temp     : set and wait
;M109 T12 S[temperature]        ; head temp    : set and wait

T2                 ; use THIRD tool position from the left    





(this page is in progress, 20 Apr 2021)