Line 11: | Line 11: | ||
* '''BLACK''' entries are for every machine | * '''BLACK''' entries are for every machine | ||
* <span style="color: forestgreen;">'''GREEN'''</span> entries are recommended, but must be manually entered | * <span style="color: forestgreen;">'''GREEN'''</span> entries are recommended, but must be manually entered | ||
* <span style="color: firebrick;">'''RED'''</span> entries are for the EHR only | * <span style="color: firebrick;">'''RED'''</span> entries are for the EHR only, and MUST be edited by hand | ||
* <span style="color: navy;">'''BLUE'''</span> entries are for the 16A only | * <span style="color: navy;">'''BLUE'''</span> entries are for the 16A only, and MUST be edited by hand | ||
* <span style="color: darkorchid;">'''PURPLE'''</span> entries are explanations | * <span style="color: darkorchid;">'''PURPLE'''</span> entries are explanations | ||
* <span style="color: darkorange;">'''GOLD'''</span> entries are optional, but recommended | * <span style="color: darkorange;">'''GOLD'''</span> entries are optional, but recommended | ||
Line 38: | Line 38: | ||
G28 X0 Y0 ; home, goto : X and Y | G28 X0 Y0 ; home, goto : X and Y | ||
<span style="color: darkorange;">M229 E1 D1 ; enable E-values (volumetric) | <span style="color: darkorange;">M229 E1 D1 ; enable E-values (volumetric) | ||
<span style="color: firebrick;">M660 H# Z# ; sets Z offset on EHR | |||
G0 X0 Y0 H# ; applies Z offset on EHR | |||
<span style="color: black;">; '''HEAD DESIGNATION''' : | <span style="color: black;">; '''HEAD DESIGNATION''' : |
Revision as of 19:56, 20 April 2021
At Hyrel, we believe that you must start with a good GCode header to get a good print. Below are explanations of our standard header files. These can be configured in Slic3r under Printer Settings > Custom G-code > Start G-code
Sample Header
- BLACK entries are for every machine
- GREEN entries are recommended, but must be manually entered
- RED entries are for the EHR only, and MUST be edited by hand
- BLUE entries are for the 16A only, and MUST be edited by hand
- PURPLE entries are explanations
- GOLD entries are optional, but recommended
This is what your header recipe will look like in Slic3r:
; REPORTING/ABORTING :
N14 ; set line numbers for error logging - Slic3r version
M772 S1 ; reset metrics and arm automatic reporting
M627 X0 Y0 Z0 J-500 K5 ; setup abort action
; RANGE SETUP
M107 ; fans/UV ; off
M106 C255 ; fans/UV ; set to 0-255 range
; OFFSETS and POSITIONING
G53 ; clear offsets
G21 ; units : mm
G91 ; coordinatess : relative
G0 Z10 ; drop bed
G90 ; coordinates : absolute
G28 X0 Y0 ; home, goto : X and Y
M229 E1 D1 ; enable E-values (volumetric)
M660 H# Z# ; sets Z offset on EHR
G0 X0 Y0 H# ; applies Z offset on EHR
; HEAD DESIGNATION :
T2 ; use THIRD tool position from the left
; TEMPERATURE CONTROL :
M190 S[bed_temperature] ; bed temp : set and wait
M109 T12 S[temperature] ; head temp : set and wait