Settings
Printer Settings
Last, you should (re)load your settings; there are several screens, detailed below.
To load a configuration file, do the following:
- Go to Setings > Printer.
- Click "Load Settings from File" (find your custom file, or the most recent one named for your model of printer)
- Make any customization you like
- Click "Flash Motion Settings"
- Click "Apply"
- Click "Save Settings To File" with your custom name, as a backup
- Click "OK"
Note that after flashing, or upon startup, you will be required to home the X and Y axes before other moves are allowed; on the EHR, you will also have to home the Z. This is so that the printer knows where you are and whether or not it is safe to move the amount you tell it to. If you unlock your motors or press the emergency stop button, you should home the X and Y axes again before making other movements (also Z on EHR).
Printer
My 30M example:
Hardware Setup
My 30M example:
Machine I/O
My 30M example:
G54 Offsets
Default values all 0.
Tool Offsets
Default values all 0.
Fixtures
Default values all 0.
Color
This page allows you to select rendering colors; you should also check the box for "show print grid" if you want it displayed by default:
My 30M example:
I/O Pins
My 30M example:
Hardware Info
Example:
Probe
Example:
Ecosystem Apps
In Repetrel, go to the Programs tab, and double click in each text field, pointing the applications to their respective executable files under C:/EcosystemApps
. See the table below for the proper locations. Note the new location for the Slic3r install; Slic3r Recipes (or Slic3r CFG files) should still be under C:\Users\Hyrel\AppData\Roaming\Slic3r
.
Program Name | Executable Location |
---|---|
Slic3r EXE | C:\EcosystemApps\Slic3r\slic3r.exe
|
Slic3r CFG | C:\Users\Hyrel\AppData\Roaming\Slic3r
|
OpenSCAD | C:\EcosystemApps\OpenSCAD\openscad.exe
|
FreeCAD | C:\EcosystemApps\FreeCAD 0.15\bin\FreeCAD.exe
|
MeshLab | C:\EcosystemApps\VCG\MeshLab\meshlab_32.exe
|
FlatCAM | C:\EcosystemApps\FlatCAM\FlatCAM.exe
|
QCAD | C:\EcosystemApps\QCAD\qcad.exe
|
TeamViewer | C:\EcosystemApps\TeamViewer\Version9\TeamViewer.exe
|
InkScape | C:\EcosystemApps\inkscape\inkscape.exe
|
GIMP | C:\EcosystemApps\GIMP 2\bin\gimp-2.8.exe
|
Note that if your login ID is not "Hyrel", you'll need to adjust the location for the Slic3r cfg file appropriately. Remember to click APPLY when done to cause these settings to be applied.
Head Settings
For Filament-based heads, see the table(s) on our Hot_Flow page.
For Reservoir-based heads, see the table(s) on our Cold_and_Warm_Flow page.