Sekret!
Using the T with the ESR and 30M
Using the T with the EHR and 16A (Single Yoke)
Using the T with the 16A (Dual Yoke)
Special Addresses
Description | T Command | T Variable | Position Ω |
---|---|---|---|
All Devices | n/a | M# T0 | n/a |
All Heads | n/a | M# T100 | n/a |
Yoke 1, All Slots | n/a | M# T10 | n/a |
Yoke 2, All Slots | n/a | M# T20 | n/a |
Aux Port | T10 | n/a | ? |
CO2 Laser | T11 | M# T41 | 22,000 |
3-Phase Spindle | T12 | M# T26 | 560 |
Primary Bed/Chamber | n/a (T13) | M# T91 | 0 |
Secondary Bed/Chamber | n/a (T14) | M# T92 | 12,000 |
All Beds/Chambers | n/a | M# T90 | n/a |
Gcodes the customer shouldn't need
M670 Toggle Y-Arm Light Now
Turn on Y-arm light immediately.
M671 Toggle X-Arm Lights
Toggle X-arm Lights
M672 Toggle Y-Arm with Sensor
See main Gcode page.
M673 Toggle Y-Arm Light Next
Toggle Y-arm light after all previous commands are finished.
M797 Report Sensors
Generates a text report of sensor states in 3D-View text window!
M797 I1 reports what is homed and what is not:
>GB: AX ST DR HM L1 L2 FT >GB: == == == == == == == >GB: X 1 1 1 0 0 1 >GB: Y 1 1 0 0 0 1 >GB: Z 1 0 1 0 0 1 >GB: A 0 0 1 0 0 1 >GB: B 0 0 0 0 0 0 >GB: C 0 0 0 0 0 0
AX - Axis ST - Step DR - Direction HM - Home L1 - Limit 1 L2 - Limit 2 FT - Fault